English
WxS8800

WxS8800

LoRa Smart IoT and RTU 2-in-1 Terminal

0.00
0.00
  

LoRa Smart IoT and RTU 2-in-1 Terminal


WxS8800


LoRa Smart IoT and RTU 2-in-1 Terminal


Related Products

Product .         Interf.                           Descriptions

WxS8800     11MPI+RS485+OD*2+PWR*2    LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx00, PSB-BD01, &  Enclosure)

WxS8801     RS485+OD*2+PWR*2         LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx01, PSB-BD01, & Enclosure)

WxS8802     0-20mA*1+OD*2+PWR*2 LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx02, PSB-BD01, & Enclosure)

WxS8803     0-20mA*4+OD*2+PWR*2 LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx03, PSB-BD01, & Enclosure)

WxS8804     0-3.3V*2+OD*2+PWR*2    LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx04, PSB-BD01, & Enclosure)

WxS8805     0-3.3V*4+OD*2+PWR*2    LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx05, PSB-BD01, & Enclosure)

WxS8806     0-10V*2+OD*2+PWR*2     LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx06, PSB-BD01, & Enclosure)

WxS8807     0-10V*4+OD*2+PWR*2     LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx07, PSB-BD01, & Enclosure)

WxS8808     PT100*1+OD*2+PWR*2    LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx08, PSB-BD01, & Enclosure)

WxS8809     PT100*5+OD*2+PWR*2    LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx09, PSB-BD01, & Enclosure)

WxS880A     Switch*1+OD*2+PWR*2    LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0A, PSB-BD01, & Enclosure)

WxS880B     Switch*5+OD*2+PWR*2    LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0B, PSB-BD01, & Enclosure)

WxS880C     Unibus*1+OD*2+PWR*2   LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0C, PSB-BD01, & Enclosure)

WxS880D     Unibus*18+OD*2+PWR*2 LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0D, PSB-BD01, & Enclosure)

WxS880E     IIC*1+OD*2+PWR*2            LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0E, PSB-BD01, & Enclosure)

WxS880F     SPI*1+OD*2+PWR*2           LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0F, PSB-BD01, & Enclosure)

WxS880G     Uart*2+OD*2+PWR*2        LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0G, PSB-BD01, & Enclosure)

WxS880H     Uart*3+OD*2+PWR*2        LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0H, PSB-BD01, & Enclosure)

WxS880J      Uart*1+RS485+OD*2+PWR*2  LoRa Smart IoT and RTU 2-in-1 Terminal (Inc. WxS88xx, PSM-xx0J, PSB-BD01, &  Enclosure)

WxS8850     Ai/Ao/Di/Pi/Ro/IIC/SPI/Ci + RS232/485/Ro/RJ45  LoRaWAN Smart RTU


Product Highlights

v  Interfaces supported:

o    MPI:(AIN(0-20mA)*2, PT100*1, VIN(0-10V/0-3.3V)*2, Switch*1 ,Unibus*1, IIC *1SPI*1, Uart(3.3V TTL)*2), RS485*1

o    RTU interfaces

§  OD*2 output for external devices controlling

§  PWR*2 output for external devices/sensors power supply or customization usage

v  2-in-1 DC(5V/12V)+Battery(3.6V Li-SOCl2 ER34615H/M) Power Supply, DC in priority

v  Up to 8 working simultaneously including sensors and controllers; Customization needed if more than 8 working at the same time

v  Built-in sensor options including:

o    PSS-403011 IIC         Temperature and Humidity Sensor (Indoor)

o    PSS-403012 RS485      Temperature and Humidity Sensor (Indoor)

o    PSS-403013 IIC          Temperature and Humidity Sensor (IP67,Outdoor)

o    PSS-403014 RS485     Temperature and Humidity Sensor (IP67,Outdoor)

o    PSS-403021 IIC         Temperature+Humidity+Barometric Pressure Sensor(Indoor)

o    PSS-403022 RS485     Temperature+Humidity+Barometric Pressure Sensor(Indoor)

o    PSS-403031 IIC         Temperature+Humidity+Barometric Pressure+Light Sensor(Indoor)

o    PSS-403032 RS485     Temperature+Humidity+Barometric Pressure+Light Sensor(Indoor)

o    PSS-423011 Uart        AQI(PM2.5/10, SO2,NO2, O3, CO,Temp,Humidity) PPM Level Sensors

o    PSS-423031 Uart        IAQ(PM2.5/10, CO2, HCHO, Temp,Humidity) Sensors

o    PSS-423041 Uart     IAQ(PM2.5/10, CO2, TVOC, Temp,Humidity) Sensors

o    PSS-423051 Uart        IAQ(PM2.5/10, CO2, HCHO, TVOC,Temp,Humidity)Sensors

o    PSS-318711 Uart       GPS/Beidou Positioning Sensor

o    PSS-318712 RS485   GPS/Beidou Positioning Sensor

o    PSS-319311 0-3.3V  Tilt / Inclination Sensor (SHM- Structure Health Monitoring)

o    PSS-333051 0-3.3V  PIR  Sensor (3-4 Meters)

o    PSS-333052 0-3.3V  PIR  Sensor (up to 20 Meters)

o    PSS-334061 0-3.3V   UV Sensor (Range:0-15 grade, outdoor)

o    PSS-355051 Switch    Uni-Call Button & Controller

o    PSS-362011 Uart       Sound/Noise Sensor (30~130dB range, Indoor)

o    All Gas Sensors with Product No. PSS-21xxxx

v  Support 1-8 enclosure externally connected sensors

o    All enclosure external PSS sensors w/o separate power supply

v  RTU OD & PWR(PWM) output control interfaces

o    OD output control interface for controlling external devices such as electric relay,AC contactor, beeper, draught fan, lamps and lantern etc.

o    PWR*2 output, one default for external devices/sensors power supply voltage output, one with 3.3V voltage; or customization usage,such as for PWM port

o    PWR port signal can be used as PWM output to control stepper moter or lamp

o    Sensor(s) data or OTA Command triggered OD/PWR controlling signal & interfaces

v  Power supply options:

o    PSB-BT01     WxS Terminal Battery Power (3.6VDC Output) (3.6V Li-SOCl2 ER34615H/M)

o    PSB-BT02   WxS Terminal Battery Power Board (3/5/9/12VDC Output) (3.6V Li-SOCl2 ER34615H/M)

o    PSB-DC01    WxS Terminal DC Power Board (Inc. PSP-DC012V)

o    PSB-BD01   WxS Terminal Battery (3.6V Li-SOCl2 ER34615H/M) & DC Power Board(Inc. PSP-DC012V)

o    Battery capacity ER34615H: 19000mAh/ER34615M: 13500mAh

v  iEdge 4.0 terminal enclosure options

o    ENC-102001 WxS Series 4.0 Enclosure(φ145x90x55mm, IP67)

o    ENC-102002 WxS Series 4.0 Poromeric  Enclosure(φ145x90x59mm)

o    ENC-102003 WxS Series 4.0 High Poromeric Enclosure(φ145x90x70mm)

v  Terminal and sensor parameters configurable with Configuration Tool running on PC

o    LoRaWAN ISM Global Bands Supported and SW Configurable

o    LORaWAN Uplink Transmission Cycle Configurable

o    Sensor Parameters Configurable

o    Sessor Data Report Cycle Configurable

v  FOTA (Over The Air) firmware upgrade, including to upgrade loader and application images

v  OTA (Over The Air) terminal running parameters supported including output signal

v  Low power consumption, years of battery operational life with 3.6V Li-SOCl2 ER34615H/M Battery with various scenarios

v  Integrated internal antenna, or optional external SMA/IPEX antenna

v  The transmission reaches 5km in NLoS (non-line of sight) and 18km in LoS (line of sight) environment

v  LoRaWAN Compliance


Specifications

Parameters

Value

Smart Terminal

Interfaces

MPI Interfaces-Any Mixture of Following:

MPI:(AIN(0-20mA) *2, PT100 *1, VIN(0-10V/0-3.3V) *2,   Switch *1 ,Unibus*1, IIC *1SPI*1, Uart(3.3V TTL)*2), RS485*1

Output Control:    OD*2 & PWR*2

Data Report

Cross-threshold report, plus periodic report (the   threshold and the periodic report cycle are both user-configurable)

Intensive data sampling and averaging

Support intensive data   sampling and averaging to improve data accuracy

Wireless

ISM Regional Parameters

AS923 (AS923-1, AS923-2, AS923-3, AS923-4)

AU915

CN470 CN779

EU433

EU868

IN865

KR920

RU864

US915

Maximum Link Budget

168dB

Distance

Up to 5km in NLOS; up to 18km in LOS

Antenna

Integrated internal antenna or external 1/2   wavelength whip antenna (SMA)

Mechanical

Dimension

3 Enclosure options with different size

WxS Series 4.0 Enclosure(φ145x90x55mm, IP67)

WxS Series 4.0 Poromeric  Enclosure(φ145x90x59mm)

WxS Series 4.0 High Poromeric   Enclosure(φ145x90x70mm)

IP rating

IP65 & IP67

Operating Temperature

-40C to +85C

Total Weight

150 g

Electrical

Supply Voltage

3.6VDC

Power Type

Replaceable 1 ER34615H/M 3.6V Li-SOCI2 Battery   (H/M); DC 4.5V – 12V optional

Compliance/Certification

LoRaWAN 1.0.2

     

 

FCC(America): 2AO7W-WXS8000,

IC(Canada): 23701-WXS8000

CE(European Union)B1810246

ROHS(European Union): R2BJ180927F0664E

Configuration Tool

v  iEdge4.0 WxS IoT Terminal products can be configured with PolySuite software-visual based Configuration Tool or CLI interface command or OTA via IoT platform, such as PolySuite PaaS platform iView.

v  Download linkhttps://ota.polysense.online/wincc/ConfigurationTool.rar

Installation Guide  

v  Below diagram shows the general installation guide for WxS8800, it can be installed on any flat and solid surface:














v  Below is the recommendation of the self-tapping screw and its sizes:

Product Images

v  WxS Series 4.0 Enclosure(φ145x90x55mm, IP67)


v  WxS Series 4.0 Poromeric  Enclosure(φ145x90x59mm)

v  WxS Series 4.0 High Poromeric Enclosure(φ145x90x70mm)






上一个: None
下一个: None